Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.9752426

- Product Categories
- Friendly Links
Information Name: | Siemens PROFIBUS bus cable |
Published: | 2013-08-23 |
Validity: | 300 |
Specifications: | 6XV1 830-0EH10 |
Quantity: | 18000.00 |
Price Description: | |
Detailed Product Description: | Siemens PROFIBUS bus cable Order No. 6XV1 830-0EH10 Siemens PROFIBUS bus cable Order No. 6XV1 830-0EH10 Electrical Technology Co., Ltd. Shanghai Tang Xi (Siemens authorized agents) Contact: Du Zhenmin (Sales Manager) 24-hour sales technical service hotline: 18516117969 Phone (Tel): 021-61551359 Fax (Fax): 021-37004235 Work (QQ): 58944023 E-mail (Email) :: 58944023@qq.com address (Add): Le Road, Songjiang District, Shanghai, No. 128 May 1021 Amoi World -1022 Shanghai Tang Xi Electrical Technology Co., Ltd. Siemens products bearing if quality assurance, welcome to inquire high quality Siemens drives and automation product prices S7-200 S7-300 S7-400 S7-1200 touch screen, inverter, 6FC, 6SN S120 V10 V60 V80 servo CNC spare parts: all kinds of motor: imported motors (1LA7, 1LG4, 1LA9, 1LE1), domestic motor (1LG0, 1LE0); dedicated motor, large motors (1LA8, 1LA4, 1PQ8); servo motor (1PH , 1PM, 1FT, 1FK, 1FS) Siemens security within the new and original product! One year warranty! Year due to product quality problems free replacement product, do not charge any fees Siemens PROFIBUS bus cable Order No. 6XV1 830-0EH10 Siemens PROFIBUS bus cable 6XV1 830-0EH10 Order Order 6XV1 830-0EH10 6XV1 831-2A 6XV1 830-0JH10 6XV1 830-0GH10 Product Type Description PROFIBUS FC standard cable PROFIBUS FC Standard Cable IS GP PROFIBUS FC high-strength cables PROFIBUS FC? cable suitable for the food industry uses Multi-Purpose cables for intrinsically safe distributed I / O systems for corrosive environments and mechanical stress serious condition of food, beverages and tobacco manufacturing cables name 02YSY (ST) CY 1 × 2 × 0.64/2.55-1 50 KF 40 FR VI 02YSY (ST) CY 1 × 2 × 0.65/2.56 BL KF40 FR 02YSY (ST) CY 1 × 2 × 0.64/2.55-150 KF 40 FR VI 02YSY (ST) C2Y 1 × 2 × 0.64/2.55-1 50 KF 40 electrical data unit length attenuation measurements at 16 MHz maximum 42 dB / km 42 dB / km 42 dB / km 42 dB / km 4 MHz maximum 22 dB / km 22 dB / km 22 dB / km 22 dB / km 38.4 kHz maximum 4 dB / km 4 dB / km 4 dB / km 4 dB / km 9.6 kHz maximum 2.5 dB / km 2.5 dB / km 2.5 dB / km 2.5 dB / km 9.6 kHz lower characteristic impedance of 270 Ω 270 Ω 270 Ω 270 Ω 9.6 kHz lower characteristic impedance relative symmetry error ± 10% ± 10 % ± 10% ± 10% 38.4 kHz under the characteristic impedance of 185 Ω 185 Ω 185 Ω 185 Ω 38.4 kHz under the characteristic impedance of the relative symmetry error of ± 10% ± 10% ± 10% ± 10% Characteristic impedance, 3 MHz ... @ 20 MHz 150 Ω 150 Ω 150 Ω 150 Ω characteristic impedance is relatively symmetrical tolerance, 3 MHz ... 20 MHz is ± 10% ± 10% ± 10% ± 10% nominal characteristic impedance of 150 Ω 150 Ω 150 Ω 150 Ω loop resistance per unit length, maximum 110 Ohm / km 110 Ohm / km 110 Ohm / km 110 Ohm / km Shield resistance per unit length, max 9.5 Ohm / km 9.5 Ohm / km 9.5 Ohm / km 9.5 Ohm / km 1 kHz the capacitance per unit length 28.5 nF / km 28.5 nF / km 28.5 nF / km 28.5 nF / km Operating voltage (rms) 100V 100V 100V 100V mechanical data sheathed cable jacket material PVC PVC PUR PE cable sheath diameter 8 mm 8 mm 8 mm 8 mm cable sheath diameter of symmetry error 0.4 mm 0.4 mm 0.4 mm 0.4 mm cable sheath color purple blue purple black ambient temperature during operation -40 ... +75 ° C -40 ... +75 ° C -40 ... +60 ° C -40 ... +60 ° C during transport -40 ... +75 ° C -40 ... +75 ° C -40 ... +60 ° C -40 ... +60 ° C during storage -40 ... +75 ° C -40 ... +75 ° C -40 ... +60 ° C -40 ... +60 ° C Installation -40 ... +75 ° C -40 ... +75 ° C -40 ... +60 ° C -40 ... +60 ° C Bending radius can be one bend, the minimum allowable value 75 mm 75 mm 75 mm 75 mm can be repeated bending, the minimum allowable value 150 mm 120 mm 150 mm 150 mm maximum tension load of 100 N 100 N 100 N 100 N Unit Length Weight 76 kg / km 80 kg / km 73 kg / km 67 kg / km Combustion flame retardant according to IEC 60332-3-24 Category C flame retardant according to IEC 60332-3-24 Category C Flame retardant standard IEC 60332-1 combustible chemical corrosion resistance to mineral oils conditional conditional tolerance tolerance conditionally resistant to oils tolerance tolerance tolerance conditional conditional conditional tolerance tolerance tolerance conditionally UV radiation tolerance tolerance tolerance tolerance performance halogen free silicone resin √ XXXX √ √ √ FastConnect electrical connection type √ √ √ √ UL certification / Rating 300 V √ / CMG/CL3 / sunscreen √ / CMG/CL3 / sunscreen √ / CMX X UL certification / Rating 600 V √ √ XX Order 6XV1 830 -3FH10 6XV1 831-2K 6XV1 830-3EH10 6XV1 830-0LH10 Product Type Description PROFIBUS FC grounding cable PROFIBUS FC Flexible Cable PROFIBUS FC Trailing cable PROFIBUS FC FRNC cable suitable for use underground GP occasionally moving machine parts used in cable trays without halogen flame retardant cable application name 02YSY (ST) CY2Y 1 × 2 × 0.64/2.55-1 50 KF 40 SW 02YH (ST) C11Y 1 × 2 × 0.64/2.56-1 50 LI KF 40 FRNC FC VI 02YY (ST) C11Y 1 × 2 × 0.64/2.55-150 LI KF 40 FR petrol 02YSH (ST) CH 1 × 2 × 0.64/2.55-1 50 VI KF 25 FRNC electrical data unit length attenuation measurements at 16 MHz maximum 42 dB / km 49 dB / km 49 dB / km 42 dB / km 4 MHz maximum 22 dB / km 25 dB / km 25 dB / km 22 dB / km 38.4 kHz maximum 4 dB / km 4 dB / km 4 dB / km 4 dB / km at 9.6 kHz maximum 2.5 dB / km 3 dB / km 3 dB / km 2,5 dB / km 9.6 kHz lower characteristic impedance 270 Ω 270 Ω 270 Ω 270 Ω Relative symmetrical tolerance of 9.6 kHz lower characteristic impedance ± 10% ± 10% ± 10% ± 10% 38.4 kHz under the characteristic impedance of 185 Ω 185 Ω 185 Ω 185 Ω Relative symmetrical tolerance of the characteristic impedance of 38.4 kHz ± 10% ± 10% ± 10% ± 10% Characteristic impedance, 3 MHz. .. 20 MHz at 150 Ω 150 Ω 150 Ω 150 Ω characteristic impedance is relatively symmetrical tolerance, 3 MHz ... 20 MHz is ± 10% ± 10% ± 10% ± 10% nominal characteristic impedance of 150 Ω 150 Ω 150 Ω 150 Ω loop resistance per unit length, maximum 110 Ohm / km 133 Ohm / km 133 Ohm / km 110 Ohm / km Shield resistance per unit length, max 9.5 Ohm / km 14 Ohm / km 14 Ohm / km 9.5 Ohm / km at 1 kHz capacitance per unit length 28.5 nF / km 28 nF / km 28 nF / km 29 nF / km Operating voltage (rms) 100V 100V 100V 100V mechanical data sheathed cable jacket material PE / PVC PUR PUR FRNC cable sheath diameter 10.8 mm 8 mm 8 mm 8 mm cable sheath diameter symmetrical error 0.5 mm 0.4 mm 0.4 mm 0.4 mm Cable Jacket Color Black Dark Brown Light Purple Purple ambient temperature during operation -40 ... +60 ° C -20 ... +60 ° C -40 ... +60 ° C -25 ... +80 ° C during transport -40 ... +60 ° C -40 ... +60 ° C -40. .. +60 ° C -25 ... +80 ° C during storage -40 ... +60 ° C -40 ... +60 ° C -40 ... +60 ° C -25 ... + 80 ° C during installation -40 ... +60 ° C -40 ... +60 ° C -40 ... +60 ° C -25 ... +80 ° C Bending radius can be one bend, the minimum allowable value of 80 mm 40 mm 40 mm 60 mm can be repeated bending, the minimum allowable value 160 mm 120 mm 120 mm 80 mm bending cycles - 3 000 000 - maximum tension load 100 N 100 N 100 N 100 N 117 kg weight per unit length / km 70 kg / km 70 kg / km 72 kg / km combustion characteristics of combustible flame retardant standard IEC 60332-1-2 IEC 60332-1-2 standard flame retardant flame retardant according to IEC 60332-3-24 C class, IEC 60332-3-22 A class resistance to chemical corrosion resistance to mineral oils conditional conditional tolerance tolerance tolerance tolerance resistant to oils conditional conditional conditional tolerance tolerance tolerance tolerance to radiation resistance conditionally UV radiation tolerance tolerance tolerance tolerance performance halogen X √ X √ silicone resin √ √ √ √ FastConnect electrical connection type √ √ √ √ UL certification / Rating 300 VX √ / CMX √ / CMX √ / CM/CL3 / sunscreen UL listed / rated 600 VXXX √ Order 6XV1 830-3GH10 6XV1 830-0PH10 6XV1 830-0MH10 Product Type Description PROFIBUS PROFIBUS cables hanging torsion cable SIENOPYR FR marine cable hanging accessories suitable for use Classification Society certification for moving machine parts Cable Name 02YS (ST) CY 1 x 2 x 0.65/2.56 LI petrol FR 02Y (ST) C 11Y 1 x 2 x 0.65/2.56-150 LI FR VI M-02Y (ST) CH X 1 x 2 x 0.35 100 V electrical data unit length attenuation measurements at 16 MHz 49 dB / km 49 dB / km 45 dB / km 4 MHz at 25 dB / km 25 dB / km 22 dB / km 38.4 kHz at 4 dB / km 3 dB / km 5 dB / km 9.6 kHz at 3 dB / km 2.5 dB / km 3 dB / km characteristic impedance of 9.6 kHz 270 Ω 270 Ω 250 Ω Relative symmetrical tolerance of the characteristic impedance of 9.6 kHz ± 10 % ± 10% ± 10% characteristic impedance of 38.4 kHz 185 Ω 185 Ω 185 Ω Relative symmetrical tolerance of the characteristic impedance of 38.4 kHz ± 10% ± 10% ± 10% Characteristic impedance, 3 MHz ... 20 MHz at 150 Ω 150 Ω 150 Ω Relative symmetrical tolerance of 3 MHz ... 20 MHz lower characteristic impedance ± 10% ± 10% ± 10% nominal characteristic impedance of 150 Ω 150 Ω 150 Ω loop resistance per unit length, maximum 133 Ohm / km 98 Ohm / km 110 Ohm / km Shield resistance per unit length, maximum 19 Ohm / km 14 Ohm / km - 1 kHz capacitance per unit length under 28 nF / km 29 nF / km - Operating Voltage (RMS) 100V 100V 100V mechanical data sheathed cable jacket material PVC PUR polymer cable sheath diameter 8 mm 8 mm 10.3 mm diameter cable sheath diameter symmetrical error of 0.3 mm 0.4 mm 0.5 mm cable jacket color brown purple black ambient temperature during the work -40 ... +80 ° C -25 ... +75 ° C -40 ... +80 ° C during transport -40 ... +80 ° C -40 ... +80 ° C - 40 ... +80 ° C during storage -40 ... +80 ° C -40 ... +80 ° C -40 ... +80 ° C during installation -40 ... +80 ° C -25 ... +75 ° C -10 ... +50 ° C Bending radius for one bend, the minimum allowable value 30 mm 30 mm 108 mm For repetitive bending, the minimum allowable value 70 mm 60 mm 216 mm maximum tension load of 80 N 100 N 100 N weight per unit length 64 kg / km 65 kg / km 109 kg / km combustion characteristics of flame retardant standard IEC 60332-1 Flame retardant standard IEC 60332-1-2 Flame retardant standard IEC 60332-3 - 24 chemical corrosion resistance to mineral oils conditional tolerance tolerance tolerance tolerance tolerance conditionally resistant to oils UV radiation tolerance tolerance tolerance tolerance performance silicone halogen XX √ Resin √ √ √ FastConnect electrical connection Model XXX UL certification / Rating 300 V √ / CM / CMG / PLCT / sunscreen / anti-oil √ / CMX X UL certification / Rating 600 V √ XX Association of Classification Societies - Lloyds Veritas, Germanischer Lloyd Order 6XV1 860-2R 6XV1 860-2S Product Type Description PROFIBUS standard cable PROFIBUS hybrid cable is suitable for the purpose of strengthening mixed ET 200pro ET 200pro, solder splash resistant cables (meet HD22.2 S3 / 5) Cable Name 02Y (ST) C 1x2x0.65/2.56-1 50LI LIY-Z Y 2 x 1 x 1.5 VI 02Y (ST) C 1 x 2 x 0.65/2.56-150LI LIH-Z 1 1Y 2 x 1 x 1.5 VI FRNC electrical data unit length attenuation measurements at 16 MHz 49 dB / km 49 dB / km 4 MHz at 25 dB / km 25 dB / km 9.6 MHz at 3 dB / km 3 dB / km Characteristic impedance at 9.6 kHz 270 Ω 270 Ω 38.4 kHz at 185 Ω 185 Ω 3 MHz ... 20 MHz at 150 Ω 150 Ω 150 Ω 150 Ω Ratings characteristic impedance symmetry error 3 MHz ... 20 MHz at ± 15 Ω ± 15 Ω 38.4 kHz when ± 18.5 Ω ± 18.5 Ω 9.6 MH is ± 27 Ω ± 27 Ω loop resistance per unit length, maximum 138 Ohm / km 138 Ohm / km Shield resistance per unit length, maximum 10 Ohm / km 10 Ohm / km 1 kHz under capacitance per unit length 30 nF / m 30 nF / m operating voltage (RMS) 300V 300V 25 ℃ when the continuous current supply conductors 7.5 A 7.5 A Mechanical Data Cable sheath material PVC PUR outer diameter 11 mm 11 mm color type Purple Purple The following dimensions 10.5 mm 10.5 mm 11.5 mm 11.5 mm dimensions above supply conductors conductor cross-sectional area of ??1.5 mm 1.5 mm wire insulation color black black ambient temperature during installation -40 ... +75 ° C -40 ... +75 ° C Operating During -40 ... +75 ° C -40 ... +75 ° C during storage -40 ... +75 ° C -40 ... +75 ° C during transport -40 ... +75 ° C -40 ... +75 ° C Bending radius one bend 44 mm 44 mm 125 mm 125 mm repeated bending bending frequency - 3 000 000 maximum tension load of 450 N 450 N Unit Length Weight 140 kg / km 135 kg / km combustion characteristic impedance combustion performance flame retardant standard IEC 60332-1-2 IEC 60332-1-2 compliant mineral oil resistance, chemical corrosion resistance, resistance to grease conditional conditional tolerance tolerance tolerance tolerance anti-ultraviolet radiation XX product performance without silicone resin halogen X √ √ √ FastConnect electrical connection type XX UL certification / Rating 300 V √ / CMG √ / CMX UL certification / Rating 600 VXX |
Admin>>>
You are the 10387 visitor
Copyright © GuangDong ICP No. 10089450, Electrical Technology Co., Ltd. Shanghai Tang Xi All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 10387 visitor
Copyright © GuangDong ICP No. 10089450, Electrical Technology Co., Ltd. Shanghai Tang Xi All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility