Welcome To b2b168.com, Join Free | Sign In 
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
 | No.9752426
 | No.9752426
 | No.9752426
 | No.9752426
- Product Categories
- Friendly Links
| Information Name: | Siemens CP5613A2 communication card | 
| Published: | 2013-08-23 | 
| Validity: | 300 | 
| Specifications: | 6GK1 561-3AA01 | 
| Quantity: | 99.00 | 
| Price Description: | |
| Detailed Product Description: | Siemens CP5613A2 communication card number 6GK1 561-3AA01 Siemens CP5613A2 communication card number 6GK1 561-3AA01 Siemens CP5613A2 communication card number 6GK1 561-3AA01 Electrical Technology Co., Ltd. Shanghai Tang Xi (Siemens authorized agents) Contact: Du Zhenmin (Sales Manager ) 24-hour sales technical service hotline: 18516117969 Telephone (Tel): 021-61551359 Fax (Fax): 021-37004235 Work (QQ): 58944023 E-mail (Email) :: 58944023@qq.com address (Add): Shanghai Songjiang District Road 128 month Songle Amoi World 1021-1022 Shanghai Tang Xi Electrical Technology Co., Ltd. Siemens products bearing if quality assurance, welcome to inquire high quality Siemens drives and automation product prices S7-200 S7-300 S7-400 S7 -1200 touch screen, inverter, 6FC, 6SN S120 V10 V60 V80 servo CNC spare parts: all kinds of motor: imported motors (1LA7, 1LG4, 1LA9, 1LE1), domestic motor (1LG0, 1LE0); dedicated motor, large motors (1LA8 , 1LA4, 1PQ8); servo motor (1PH, 1PM, 1FT, 1FK, 1FS) Siemens security within the new and original product! One year warranty! Year due to product quality problems free replacement product, do not charge any fees Siemens CP5613A2 communication card number 6GK1 561-3AA01 Siemens CP5613A2 communication card number 6GK1 561-3AA01 Siemens CP5613A2 communication card number 6GK1 561-3AA01 via dual-port - RAM can be the fastest way to access process data. OPC as standard interface a data processing (DP) cycle data consistency with the process by reducing the host CPU load, more computing power via plug and diagnostic tools and fast commissioning. By supporting constant bus cycle time can be used for motion control applications, dual-port-RAM interface is easily portable to other operating systems. Even in high temperature industrial environments also implemented. With PCI 3.3/5V, 33/66 MHz and 64-bit PCI-X compatible slot, the flexibility for PG / PC PROFIBUS DP to DP Access to process data CP 5613 A2 as PROFIBUS DP master operation, It will process image (input data, output data and diagnostic data) is stored in the DP-RAM inside (CP storage area). CP 5613 A2 hardware independent and PROFIBUS slaves for high-performance data exchange. Directly accesses the dual-port RAM. Slave process data is always the same, such as the user from the same DP cycle access to data and DP5613 DP-Base software running in parallel is not allowed. Event / filter mechanism to access the user through two mechanisms receive the latest data: Cyclic polling of the DP slave (host CPU load is heavy) input events from the station changed through the new event / filter mode signal is given (the main CPU minimum load ) can be combined in two different ways. Therefore, it is possible to optimize the application. New event / filter mechanism can be used to send the slave diagnostic information via interrupt signal through equidistant mode interrupt signal to start the loop terminates with DP DP slave cyclic data communication FastLogic FASTLogic ie CP 5613 A2 can automatically respond to a maximum of 4 units device status. Can achieve rapid response and independent of the host application, for example: can be used to quickly stop the device. DP programming interface CP 5613 A2 of the DP programming interface (DP-BASE) has the following features: DP Master Class 1 including acyclic DP expansions DP Master Class 2 including acyclic DP expansions directly through the dual-port - RAM DP-RAM interface is not only offers fast access to the DP master, also ported to other operating system environments (such as VX Works, QNX. RMOS) foundation. After a program library (DP_BASE.DLL), provides management function calls (initialization and management services). DK-5613 development kit development kit Use Kit DK-5613, a class can access the DP master and DP slave (including acyclic DP expansions) Kit DK-5613 through the CP5613A2 and CP5614A2 communications processors can be integrated into any operating system environment. The tool includes descriptions in PDF format and the necessary source code downloaded from the Internet. To DP-5613 Access to process data in a DP master class CP 5613 A2 as a DP master class run, in line with IEC 61158/EN 50170 standard, and fully processed independently distributed stations (DP slaves) data communication. With fixed, repeating message cycle, the central controller and DP slave (eg ET 200S) to exchange information. DP programming interface (DP Lib, DLL) for the PC programmer with function calls for data transfer. In addition, DP interface provides the SYNC and FREEZE and starting from the station and release functions. Master Class 1 DP functions extended to support non-cyclic "read" and "write" function (DS_READ, DS_WRITE) as well as data-parallel execution and cyclic alarm acknowledgment (ALARM_ACK). Cyclic measured values, compared to non-cyclic transmission of data (eg parameterization data) does not change frequently, and rapid cycling of useful data transmission compared it to a lower priority transmission. In the master interrupt acknowledge, to ensure the DP slaves came from a reliable interrupt transmission. DP-Base and DP -5613 software is allowed to run in parallel. Class 2 DP master class 1 DP master in addition to services, CP 5613 A2 via the DP programming interface provides meet IEC 61158/EN 50170 Class 2 DP master services. Such equipment (programming, configuration or operating equipment) used for debugging, configuring the DP system or for normal operation (diagnostics) system operation. DP programming interface provides the following services: master slave diagnostics reading slave I / O read or change the configuration data of the DP slave address extension features include access to non-slave cycle parameters and measured values. For example: process automation and intelligent HMI devices. Startup and normal operation must provide the type and extension of the slave parameter data (DS_READ, DS_WRITE, DS_DATA_TRANSPORT). PG / OP communication This software assurance SIMATIC S5 and S7 (SIMATIC S5-95U except) controller via a PROFIBUS connection with STEP5/STEP7 programming. Installing CP5613 (DP-Base) based CP5613A2 after the PG / OP communication. No additional software package. Open communication (send / receive) based on the FDL interface is based on the FDL interface to send / receive, install CP 5613 A2 (DP-BASE), the data transfer can be thought, diagnosis and management to provide services. No additional software package. Software for S7 communication (S7-5613) SIMATIC S7 system components communicate with each other through S7 communication. S7 programming interface enables PG / PC application to access the SIMATIC S7 system components entrance. SIMATIC S7 data access is convenient and flexible. S7 communication provides the following services: Management Services connection manager tracing data transmission services small database read / write variable transmission / reception (maximum 64K bytes per task) for PROFIBUS-FMS interface software (FMS-5613) through the FMS programming interface, with FMS controller PG / PC machine (eg S5/S7) and other manufacturers can field devices to exchange data. Using the FMS to ensure open communication. FMS interface provides the following services: CRL Management Service Management Service Management Service FMS connection with the client and server object dictionary management services for the client and server variables services (read, write, information reporting) Server functionality VFD (Virtual Field equipment) for clients and servers Service Bus access information services (real-time report) tracking and small databases. User Interface OPC interface package contains each OPC server can be used as a standard programming interface, through PROFIBUS DP, open communication, S7 communication and PROFIBUS FMS protocol automation technology applications to connect to OPC Windows applications (Office, HMI systems, etc. ). Through the C language library programming interface existing applications programming interface to dynamic link library (DLL) form. You can SIMATIC NET CD products found in the Readme file compiler published site at http://www.siemens.com/automation/csi/net. Provide BorLand programming interface (eg DELPHI) AXIO solution. For other operating systems solutions, see Development Kit DK-5613. Configuration STEP 7 or NCM PC V5.1 + SP2 or later can be configured S7 communication protocol, open communications protocol, DP protocol (DP-V0/DP-V1/DP-V2) and FMS protocol. NCM PC configuration tool is included in the scope of supply PROFIBUS package. Diagnostics for the module itself and PROFIBUS DP network diagnostic tools are available (for installation, commissioning and operation). Therefore CP 5613 A2 PROFIBUS networks can be quickly and easily start. | 
Admin>>>
You are the 10387 visitor
Copyright © GuangDong ICP No. 10089450, Electrical Technology Co., Ltd. Shanghai Tang Xi All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 10387 visitor
Copyright © GuangDong ICP No. 10089450, Electrical Technology Co., Ltd. Shanghai Tang Xi All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

